1 RocketRAID 2700 6Gb/s SAS/SATA Host Adapters User’s Guide Revision: 1.0 Date: December 2009 HighPoint Technol
10 J1 This jumper supports SAF-TE interface (I2C). 1.2 – RocketRAID 2722 Port2、Port3 These
11 2 - Installing the RocketRAID Host Adapter Note: Make sure the system is powered-off before installing the RocketRAID host adapter. The RocketRAI
12 RocketRAID BIOS Utility The RocketRAID 2700 card will display it's BIOS screen during the system's boot process. Press Control + H when
13 BIOS Commands Create - this command is used to open the RAID Creation menu. Delete - this command will delete the selected RAID array. Add/R
14 Creating Arrays: Select Create from the toolbar and press Enter. 1. Use the arrow keys to select the RAID level and press ENTER. 2. Use t
15 3. On the Create menu, use the arrow keys to highlight the Select Devices item and press Enter. A device list will appear, and display all avail
16 7. Sector Size – Also known as “Variable Sector Size”. Use this option if you are using an older 32-bit Windows operating system. This allows o
17 4 - Adding/Remove Spare Disks This Add/Remove Spare command is used to assign a hard disk to act as a Spare Disk. Spare Disks are used to automat
18 HighPoint Software CD Each retail box includes a copy of the HighPoint Products Software CD. This CD can be used to generate driver diskettes, an
19 Device Driver Installation – Windows Operating Systems We recommend visiting the RocketRAID download pages for the latest Windows Devic
2 Copyright Copyright © 2009 HighPoint Technologies, Inc. This document contains materials protected by International Copyright Laws. Al
20 RocketRAID 2700 Windows Driver Installation Windows XP, 2003 Installing the RocketRAID driver for an existing Windows system After the operatin
21 3. Click on the “Include this location in the search” option, and click “Browse”. Browse to the location of the driver and click Next. 4. Wi
22 5. Click finish when prompted. When Windows asks to reboot the system, choose Yes. Installing the RocketRAID driver during a fresh Windows ins
23 RocketRAID 2700 Windows 7/Vista/Windows 2008 Driver Installation Installing the driver for an existing Windows 7, Vista and 2008 system 1. Inst
24 4. Select “I don’t have disc, show me other options”. 5. and then select “Browse my computer for driver software”. .
25 6. Browse to the location of the driver and click “Next”. 7. When asked: “Would you like to install this driver software?”, select “Install”.
26 8. Reboot the system when prompted. The RocketRAID host adapter will be ready for use after Windows reboots. Installing the driver during a f
27 Linux and FreeBSD Device Driver installation Binary and source driver updates are routinely posted for a variety of older Linux ope
28 HighPoint RAID Management Utilities (HRM) – Web GUI / CLI The HighPoint RAID Management Utility Suite, also known as “HRM”, includes
29 Debian/Ubuntu Linux Distributions – Installing the Web-based Management Utility For Debian/Ubuntu Linux distributions, you can use alien to conve
3 HIGHPOINT TECHNOLOGIES, INC... 5 HIGHPOINT ROCKETRAID 2700 SERIES – PCI-EXPRESS 2.0
30 1 - Installing the Web GUI (v1.5) - Windows Operating Systems (2000, XP, 2003, Vista, 2008, Windows 7) 1) After downloading the Web GUI, double-
31 2) The HighPoint Web RAID Management Service install screen will display. Click Next to continue: 3) Click Yes to install the Management util
32 4) Specify the Destination folder and click Next: Confirm the install location, and click Next:
33 5) Select the SAF-TE configuration file for the system’s chassis. If the system does not support SAF-TE, select the default option “Skip and Conf
34 7) Choose to enable or disable Remote Access. Remote access allows the card to be managed via a Web browser from a separate system. 8) Click
35 2 - Starting the Web GUI 1) Double-click the “HighPoint Web RAID Management” Icon on the the Desktop to start the Web GUI. The system’s default
36 3 - Web GUI – Icon Definitions The Rocket RAID Web GUI uses a variety of Icons to represent various states or functions. The followi
37 4 - Web GUI - Configuring an Array This guide assumes that the hard disks have already been installed into the external chassis, and attached to
38 Create an Array To create an array, select Manage – Array from the Web RAID Management Utility’s toolbar. This will open the Manage Array menu:
39 Foreground: The RAID initialization process will be set as high priority. The array cannot be utilized this procedure is complete, but the build
4 4 - Web GUI - Configuring an Array... 37 Initializ
40 5 - Web GUI - Configuring Spare Disks The term “Spare Disk” refers to a hard disk, or dedicated disk space, that is used to rebuild a RAID array
41 2) Click “OK” when the pop-up window is displayed. This will add the disk to the Spare Pool. 3) To remove a Spare Disk from the Spare pool, cl
42 6 - Web GUI - Recovering an Array When a redundant array’s status is ”Critical”, fault tolerance is disabled. The array is can be used in this fo
43 2) Click “Add Disk”. 3) Select the desired drive and click “submit. 4) The Web GUI will initiate the rebuild procedure, and display a progre
44 7 - Web GUI - Maintaining RAID Arrays Regular scheduled RAID Maintenance is essential to data security. We recommend routine RAID v
45 Removing Tasks 1) From the task List, Check the box before the target Task and click “Delete”.
46 SHI – Storage Health Inspector The Storage Health Inspector section provides real-time device related information including temperature readings,
47 8 - Web GUI - Safeguarding your Array The RocketRAID Host Adapter provides a number of innovative maintenance and notification features
48 Enable Audible Alarm – enable or disable the card’s alarm. The alarm will sound if the a disk or array stops responding. Event Log Path – Use th
49 9 - Web GUI - Event Notification The RocketRAID 2700 host adapters will record Administrator activity or RAID related errors to the Web GUI’s E
5 HighPoint Technologies, Inc. HighPoint Technologies, long recognized as a leader in mass storage technologies specializes in the design and manufac
50 Configuring SMTP (E-mail) Notification The Web GUI provides an SMTP notification system – this feature can be used to instruct the Web GUI to sen
51 10 - Web GUI - Advanced RAID Functions (Windows VSS, OCE/ORLM) VSS – Variable Sector Size Variable Sector size allows you specify the sector size
52 2. After selecting the block size, the Web GUI will display a warning message: Select OK to continue. Click the “Create” button once more to c
53 5. Double-click “Administrative Tools”. 6. Double-Click “Computer Management”. 7. Under “Storage”, click on the folder icon labeled “Disk
54 Disk Management 8. Click “Next” to continue
55 9. Click “Finish” to continue. 10. Right-click the “Unallocated” box and select “New Partition”. 11. Partition and format the array as de
56 Online Capacity Expansion and RAID Level Migration (OCE/ORLM) OCE/ORLM allows you to add hard disks to an existing RAID array, and/or convert the
57 a) Target Name – The GUI will ask that you enter a “new” name for reference (the previous RAID configuration will be displayed
58 4. The Web GUI will notify you when the process starts. A progress bar will be displayed under the Status column of the Manage-Array menu. 5.
59 Customer Support If you encounter any problems while utilizing the RocketRAID host adapter, or have any questions about about this or any other H
6 HighPoint RocketRAID 2700 Series – PCI-Express 2.0 RocketRAID 2710/2720/2722 HOST ADAPTER The RocketRAID 2710/272x host adapters are high-perform
60 Thank You Thank you for purchasing the RocketRAID 2700 SATAII RAID Host adapter. We appreciate your support, and welcome any questions, comments o
61 FCC Part 15 Class B Radio Frequency Interference statement This equipment has been tested and found to comply with the limits for a Class B di
7 1 - Features and Specifications Host Adapter Architecture PCI-Express x8 (Gen2) Support up to 4/8 SAS/SATA drives 1 Internal MiniSAS Conn
8 Operating System Support Windows XP, 2003, Windows Vista, Windows 2008, Windows 7 (32 and 64-bit versions) Linux (Fedora Core, Red Hat Enter
9 Hardware – Description and Installation 1.1-RocketRAID 2710/272x Host Adapter layout Illustration shows RocketRAID 2720 Port1、Po