Highpoint RocketRAID 2320 Manuale Utente

Navigare online o scaricare Manuale Utente per Alimentatori elettrici Highpoint RocketRAID 2320. HighPoint RocketRAID 2320 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 77
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
RocketRAID 2320
SATAII Host Adapter
User’s Guide
Revision: 1.0
Date: August 2005
HighPoint Technologies, Inc.
Vedere la pagina 0
1 2 3 4 5 6 ... 76 77

Sommario

Pagina 1 - SATAII Host Adapter

RocketRAID 2320SATAII Host AdapterUser’s GuideRevision: 1.0Date: August 2005HighPoint Technologies, Inc.

Pagina 2 - Trademarks

Chapter 2RocketRAID 2320Hardware Description/InstallationContents of this Chapter:RocketRAID 2320 Hardware1 - RocketRAID 2320 Adapter Layout2 - LED Co

Pagina 3 - Table of Contents

RocketRAID 2320 Hardware1 – RocketRAID 2320 Adapter LayoutPort1- Port8These represent the RocketRAID 2320’s eight SATAII channels. The SATA portfurth

Pagina 4 - Table of Contents

2 - LED ConnectionsThe RocketRAID 2320 has 4 LED jumpers – J2, J3, J4 and J5. The following diagramsdescribe the connector pin definitions for the Di

Pagina 5 - Introduction

RocketRAID 2320 LED GuideFor more information about LED support, and installation guides for various chassisconfigurations, consult the RocketRAID 232

Pagina 6 - About this Guide

4. After installing the adapter, attach hard disks to the RocketRAID 2320 using anSATA data cable. SATA cables have universal connections – either en

Pagina 7 - Array initialization

Each cross-adapter cable has a 3-pin and 4-pin connector, designed for insertion intoJP3 and JP4 respectively.Example installation:For a 16-hard disk,

Pagina 8 - Online RAID Level Migration

Chapter 3RocketRAID 2320 BIOS UtilityContents of this Chapter:RocketRAID 2320 BIOS Utility1 - BIOS Command Overview2 - Creating RAID Arrays3 - Adding/

Pagina 9 - Legacy disk

RocketRAID 2320 BIOS UtilityThe RocketRAID 2320’s BIOS Utility can be accessed using the “Ctrl+H” command.This command should be displayed automatical

Pagina 10 - Chapter 2

Add/Remove Spare - this command is used to assign hard disks to function asspare disks. The controller is capable of using spare disks to automatical

Pagina 11 - RocketRAID 2320 Hardware

2 - Creating RAID ArraysInitializing Disks:Before creating a RAID array, the disks must be initialized.Initialization writes necessary RAID configurat

Pagina 12 - 2 - LED Connections

CopyrightCopyright © 2005 HighPoint Technologies, Inc. This document contains materialsprotected by International Copyright Laws. All rights reserved

Pagina 13 - RocketRAID 2320 LED Guide

6. Next, use the ↓↓↓↓↓ arrow key to highlight the Capacity (GB) option and pressENTER. The total available capacity will be displayed. Press ENTER i

Pagina 14 - 5 - Single-RAID Cross Adapter

3 - Adding/Remove Spare DisksThis command is used to assign a hard disk to act as a Spare Disk.Spare Disks are used to automatically rebuild Redundant

Pagina 15

Chapter 4RocketRAID 2320 Driver andSoftware Installation MicrosoftWindows (2000, XP, 2003 Server)Contents of this Chapter:Driver and Software CDWindow

Pagina 16 - Chapter 3

Driver and Software CDThe RocketRAID 2320 retail box includes a Driver and Software CD.This CD can be used to generate driver diskettes, and install t

Pagina 17 - 1 - BIOS Command Overview

Click on the “Please Select the Diskette you want to create” drop-down button, andselect the appropriate OS from the list.Click on the “OK” button to

Pagina 18

To install the RAID software:Click on “Install RAID Management Software”.Select the desired software from the drop down menu, and click on the “OK” bu

Pagina 19 - 2 - Creating RAID Arrays

Windows Driver InstallationBefore installing the RocketRAID 2320 device driver, make sure the RocketRAID 2320host adapter and all required hard disks

Pagina 20 - Single RAID – Cross Adapter

2. In the popup window, select Hardware tab and then click Device Managerbutton.3. Double click the “SCSI and RAID controllers” entry. If the RocketR

Pagina 21 - 3 - Adding/Remove Spare Disks

Logging OnThe RAID Management Console requires that a user (or Administrator) log on. Thesoftware is incapable of working with RAID arrays or hard di

Pagina 22 - RocketRAID 2320 Driver and

2 - Software Interface - Overview of commands/functionsAfter logging on, several new options will become available.These commands are displayed toward

Pagina 23 - Driver and Software CD

Table of ContentsChapter 1IntroductionAbout this Guide ...

Pagina 24

OperationThis menu will list all available commands for the selected Function menu.These commands are also represented in icon/button form (below the

Pagina 25 - To install the RAID software:

3. Select the desired RAID level from the drop-down list.4. Enter a name for the array using the keyboard (this is optional), and click the Nextbutton

Pagina 26 - Windows Driver Installation

Press Enter to use the default value (the maximum capacity for the array), orspecify the desired value using the keyboard, and press Enter to confirm

Pagina 27 - XP/2003/x64 installation

5 - Configuring Spare DisksSpare disks can be used to rebuild redundant RAID arrays in the case of failure.To configure spare disks, highlight the “Ma

Pagina 28 - Logging On

2. Highlight the array that needs to be rebuilt.3. Click the Rebuild button on the toolbar or select the “Rebuild” command from the“Operation” menu.Ve

Pagina 29

To perform OCE/ORLM on an array:1. Highlight the “Management” menu, and select the “Array Management”function.2. Highlight the array you want to alter

Pagina 30 - 3 - Creating an Array

8 - Misc. Array/Device OptionsDevice ManagementThe Device Management window provides configuration information about control-lers (the RocketRAID 2320

Pagina 31

SAF-TE ManagementThis feature allows the administrator to view and monitor a variety of SAF-TE relatedattributes, such as chassis temperature readings

Pagina 32 - 4 - Deleting an Array

9 - Managing EventsThe HighPoint RAID Management Console will log all events that have occurred onany host adapter under it’s control.Viewing Logged E

Pagina 33 - 5 - Configuring Spare Disks

To add a Recipient:1. Highlight the “Management” menu, and select the “Event Notification” function.2. Click the “Add” button on the toolbar or select

Pagina 34 - 7 - OCE/ORLM

WINDOWS DRIVER INSTALLATION ...1 - Installing the RAID Management Console/ Interface

Pagina 35

To setup and schedule tasks highlight the “Management” menu, and select the “TaskManagement” function to open Task Management window.The Task Schedule

Pagina 36 - S.M.A.R.T Status

Select the task type and the array that you want to verify or rebuild, then click“Next”.RocketRAID 2320 Driver and Software Installation4-19

Pagina 37 - Renaming an Array

Enter a name for the task.Configure the frequency for the task.Set the duration for the task.Check the “Enable the task” option to activate this task.

Pagina 38 - 9 - Managing Events

10 - Configuring Remote SystemsThen HighPoint RAID Management Console manages a RAID controller through aconnection to the HighPoint RAID Management S

Pagina 39 - Managing Tasks

Modify a ConnectionThis command modifies connection information for a remote system. To modify aconnection:1. Highlight the “File” menu and select th

Pagina 40 - Add a Scheduled Task

3. Click the “Connect” button on the toolbar or select the “Connect” commandfrom the “Operation” menu.4. Enter the appropriate Login information in th

Pagina 41

System ConfigurationThis function is used to modify the service configuration on a remote system. Tochange the service configuration:1. Highlight the

Pagina 42 - Delete a Scheduled Task

11 - Configuring Users and PrivilegesThe RAID Management Console allows the Administrator to manage user accounts inits own database. You can setup mu

Pagina 43 - Add a Connection

3. Select the appropriate privileges for the user.4. Click “Finish”.Delete a UserThis function deletes a user’s account on the connected remote system

Pagina 44 - Delete a Connection

1. Select the target user ID from the user list displayed in the User Managementwindow.2. Click the “Set Password” option, and enter the password for

Pagina 45 - Disconnect Remote System

Chapter 1IntroductionContents of this Chapter:About this GuideIntroducing the RocketRAID 2320 Host AdapterProduct FeaturesUnderstanding RAID Concepts

Pagina 46 - System Configuration

Chapter 5Linux Driver SupportContents of this Chapter:Fedora Core 3 Linux installation OverviewRed Hat Enterprise 3 OverviewSuSE Linux Enterprise Serv

Pagina 47 - Add a User

1 - Fedora Core 3 Linux installation OverviewThis section provides instructions describing how to install and utilize theRocketRAID 2320 Adapter on a

Pagina 48 - Set Password

2) At the “Welcome to Fedora Linux” installation screen, a prompt labeled “boot:”will appear at the bottom of the screen. Type in linux dd, then pres

Pagina 49 - Set Privilege

After extracting the driver module, load it using the following commands:# modprobe sd_mod# insmod rr2320.koArrays attached to the adapter can be acce

Pagina 50 - Linux Driver Support

#chmod 755 /etc/init.d/hptdriver#ln –sf /etc/init.d/hptdriver /etc/rc.d/rc3.d/S01hptdriver#ln –sf /etc/init.d/hptdriver /etc/rc.d/rc4.d/S01hptdriver#l

Pagina 51 - Step 2 Install Fedora Linux

1 - Red Hat Enterprise 3 OverviewThis section provides instructions describing how to install and utilize theRocketRAID 2320 Adapter on a Red Hat Ente

Pagina 52

1. The system will now load the RocketRAID 2320 driver automatically.2. When prompted “Where do you want to install the boot loader? ” in the “BootLoa

Pagina 53

After you have extracted the driver module, you can load it by following commands:# modprobe sd_mod# insmod rr2320.oArrays attached to the adapter can

Pagina 54 - 5 - Uninstalling the Driver

#echo “modprobe rr2320” > /etc/init.d/hptdriver#chmod 755 /etc/init.d/hptdriver#ln –sf /etc/init.d/hptdriver /etc/rc.d/rc3.d/S01hptdriver#ln –sf /e

Pagina 55 - RocketRAID 2320 controller

Example: (2.4.21-4.EL for Red Hat Enterprise Linux 3.0):# gzip -dc /boot/initrd-xxx.img > /tmp/initrd.ext2# mkdir /mnt/initrd# mount -o loop /tmp/i

Pagina 56

About this GuideThe RocketRAID 2320 SATAII Host Adapter’s User’s Guide provides informationabout the functions and capabilities of the host adapter, a

Pagina 57

1 - SuSE Linux Enterprise Server (SLES) installation OverviewThis section provides instructions describing how to install and utilize theRocketRAID 23

Pagina 58

4. When the “Diver Update Menu” is displayed, press “OK” and “back” for backto installer.5. Next. Select “back” to return to the installer.6. Installa

Pagina 59

Example:default=0timeout=8title Linuxkernel (hd0,1)/vmlinux root=/dev/hda1 acpi=offinitrd (hd0,1)/initrdReboot the system to allow the new kernel para

Pagina 60 - Step 2 Install SLES Linux

Step 3 Mounting and Partitioning the DeviceNote: Many versions of SuSE include YAST. YAST is a graphical configurationutility that is capable of exec

Pagina 61 - Step 1 Update Grub

Step 5 Configure System to Mount Volumes during StartupThe system can be instructed to automatically mount the array(s) during startup bymodifying the

Pagina 62

Chapter 6FreeBSD Driver SupportContents of this Chapter:1 - Installing FreeBSD on the RocketRAID 2320 Controller2 - Installing RocketRAID 2320 Driver

Pagina 63

1 - Installing FreeBSD on the RocketRAID 2320 ControllerIf you would like to install FreeBSD onto arrays attached to the RocketRAID 2320host adapter,

Pagina 64

BIOS driver B: is disk1BIOS driver C: is disk2BIOS 636kB/74512kB available memoryFreeBSD/i386 bootstrap loader, Revision 0.8(mailto:[email protected].

Pagina 65 - FreeBSD Driver Support

for FreeBSD 4.6.2-RELEASEok load disk1:rr2320-4.6.2.kofor FreeBSD 4.7-RELEASEok load disk1:rr2320-4.7.kofor FreeBSD 4.8-RELEASEok load disk1:rr2320-4.

Pagina 66 - Step 2 Install FreeBSD

for FreeBSD 5.2.1-RELEASEok load disk0:rr2320-5.2.1.ko for FreeBSD 5.3-RELEASEok load disk0:rr2320-5.3.ko for FreeBSD 5.4-RELEASE ok

Pagina 67

Understanding RAID Concepts and TerminologyThe following concepts and terminology is commonly used when describing thefunctions of the RocketRAID 2320

Pagina 68

7. Before exiting installation, an additional step must be taken to copy theRocketRAID 2320 driver module to the system. On the driver diskette, there

Pagina 69

Alternately, it is possible extract the files from the .img files directly, without using afloppy diskette:For FreeBSD 4.x:# vnconfig vn0c freebsd_xxx

Pagina 70 - Step 1 Copy the Driver Module

>> FreeBSD/i386 BOOTDefault: 0:ad(0,a)/boot/loaderboot:BTX loader 1.00 BTX version is 1.01Console: internal video/keyboardBIOS driver A: is dis

Pagina 71 - Step 2 Test the Driver Module

Note: If you have configured a RAID 10 using 4 disks, it will be registered to systemas device /dev/da0. You can use “/stand/sysinstall” to create par

Pagina 72

3 - Updating the DriverTo update the driver with a newer revision, simply reinstall the driver following thesteps discussed in the previous section, “

Pagina 73

AppendixCustomer Support

Pagina 74 - 4 - Uninstalling the Driver

Customer SupportIf you encounter any problems while utilizing the RocketRAID 2320, or have anyquestions about this or any other HighPoint product, fee

Pagina 75 - Customer Support

FCC Part 15 Class B Radio Frequency Interference statementThis equipment has been tested and found to comply with the limits for a Class Bdigital devi

Pagina 76

Foreground initializationForeground initialization will zero-out all data on the array. The array is not accessibleby the operating system until initi

Pagina 77

Spare diskA spare disk is a single disk that can be used to automatically rebuild a redundantarray in case of drive failure. Spare disks may also be

Commenti su questo manuale

Nessun commento